1-Stage glass diffusion pump manufactured by PWL type "PDS/P-1"
This pump is called "PDS/P-1" because "Pompa Dyfuzyjna Szklana z ch³odzeniem Powietrznym - wersja 1" would be translate as "Glass diffusion pump with air cooling - version 1".
This pump is simple, homemade version of diffusion pump.

fig.1. Glass oil diffusion pump type PDS/P-1
Technical parameters:
critical pressure >10-2 Tr
ultimate pressure <5*10-5 Tr (measured by Bayard-Alpert gauge)
quantify of oil 15 ml (DC705, santovac)
power consumption 70W/230V
air cooling
kind of glass: soda
height 35 cm
latitude 10 cm
Back to PWL's page